Serverschaden
cat /proc/mdstat
Personalities : [raid1]
md2 : active raid1 sdb3[1] sda3[2]
967313728 blocks [2/1] [_U]
[###=>.] recovery = 96.1% (930478016/967313728) finish=22.1min speed=27761K/sec
md1 : active raid1 sda2[0] sdb2[1]
1052160 blocks [2/2] [UU]
md0 : active (auto-read-only) raid1 sda1[0] sdb1[1]
8393856 blocks [2/2] [UU]
unused devices: <none>
Das wäre ja nicht so schlimm, wenn nicht:
[21711.257896] ata2.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0
[21711.257911] ata2.00: irq_stat 0x40000008
[21711.257923] ata2.00: failed command: READ FPDMA QUEUED
[21711.257941] ata2.00: cmd 60/08:00:10:86:90/00:00:65:00:00/40 tag 0 ncq 4096 in
[21711.257943] res 41/40:08:10:86:90/00:00:65:00:00/00 Emask 0x409 (media error) <F>
[21711.257969] ata2.00: status: { DRDY ERR }
[21711.257979] ata2.00: error: { UNC }
[21711.277512] ata2.00: configured for UDMA/133
[21711.277530] sd 1:0:0:0: [sdb] Unhandled sense code
[21711.277534] sd 1:0:0:0: [sdb] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE
[21711.277540] sd 1:0:0:0: [sdb] Sense Key : Medium Error [current] [descriptor]
[21711.277547] Descriptor sense data with sense descriptors (in hex):
[21711.277551] 72 03 11 04 00 00 00 0c 00 0a 80 00 00 00 00 00
[21711.277564] 65 90 86 10
[21711.277570] sd 1:0:0:0: [sdb] Add. Sense: Unrecovered read error - auto reallocate failed
[21711.277578] sd 1:0:0:0: [sdb] CDB: Read(10): 28 00 65 90 86 10 00 00 08 00
[21711.277591] end_request: I/O error, dev sdb, sector 1703970320
[21711.277639] ata2: EH complete
Und ja, ist ein RAID1, und ja, die kaputte sda
war der Grund warum der resync
überhaupt nötig geworden war. Einmal ist der resync
bereits gescheitert. Beide Platten waren unter ein halbes Jahr alt.